Cabinet Moving Test. This test shall be conducted on one cabinet of each type, class, and size. The load area for all shelves shall be the entire top of the shelf minus three inches from each side. Coat rods shall be loaded across the entire width of the rod, minus 2 inches on the side. All shelves shall be spaced as equidistant as possible between each other and between the top and bottom of the cabinet. Shelves, bottoms and coat rods shall be loaded with weights in the amounts shown in table below. The cabinets shall be pushed or pulled at a rate of approximately 3 feet per second for a distance of not less than 25 feet, across a concrete or tile floor. The force shall be applied at a height of 36 to 42 inches above the floor. The weights shall be removed and the cabinets examined to determine that no part of the cabinet suffered any permanent deformation. Also, there shall be no cracked or broken welds, or any looseness of mechanical attachments
|
|
|
Shelves |
Bottom |
Coat Rod |
Type I, |
Class 1, |
Size 1 & 2 |
30 |
30 |
|
|
Class 2, |
Size 3 & 4 |
15 |
20 |
|
Type II, |
Class 1, |
Size 1 & 2 |
15 |
20 |
15 |
Type III, |
Class 1, |
Size 1 |
30 |
30 |
25 |
|
|
Size 2 |
|
30 |
25 |
|
Class 2, |
Size 3 |
15 |
20 |
15 |
|
|
Size 4 |
|
20 |
15 |
Regulatory Requirement. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practicable.
Packaging, packing and marking. Packing, packing and marking shall be in accordance with the solicitation.
Standard Color. A sample of the specified enamel color is obtainable from the Business Service Center, Federal Supply Service, General Services Administration, Washington, DC 20407 or from the Business Service Center in the nearest General Services Administration Regional Office.